Honeywell V4043H1106 28mm Zone Valve, 24 V

£123.495
FREE Shipping

Honeywell V4043H1106 28mm Zone Valve, 24 V

Honeywell V4043H1106 28mm Zone Valve, 24 V

RRP: £246.99
Price: £123.495
£123.495 FREE Shipping

In stock

We accept the following payment methods

Description

The auxiliary circuit (grey and orange wires) is commonly used to operate the boiler and/or the circulating pump. The auxiliary circuit could be set to work at a lower voltage than mains but it is normally carrying mains voltage. It works like this: One of the two wires, typically the grey, is connected to a permanent mains Live supply (about 230V AC in the UK). The other wire, usually the orange, is connected to the Switched Live feed to the boiler. If you know how to work safely with mains voltage electricity, the valve motor can be tested with a multimeter. With the mains electrical supply turned off and isolated, the resistance across the two motor wires (either both blue or both orange) can be tested. To test correctly, at least one of the two motor wires must be disconnected from the heating wiring circuit. You should be able to feel a bit of spring resistance, right at the far end (Man Open end) of the slot.

With the powerhead cover removed you also have access to the screw which retains the motor. The motor can, if necessary, be removed without disconnecting the powerhead from the valve body. The commonest fault with Honeywell motorised valves is motor failure. Honeywell valve motor fault? Testing a Synchron valve motor

When all electrical power to the heating controls is switched off, the spring pulls the ball across to close port A, leaving port B open. This is the relaxed state or de-energised state of the valve. It is also sometimes called the Normal state. Where two 2-port motorised valves are fitted (one for the heating circuit and one for the hot water cylinder circuit) the fault may be disguised. Even though one valve only partly opens itself and is unable to fire the boiler, the valve on the other circuit can open fully and fire the boiler. The pump then pushes heated boiler water through both the open valve and the partially open valve. Replacement Honeywell SYNCHRON motors are available but are a bit more expensive. For a long time we’ve used the standard SYNCHRON motors as replacements, with very few problems. On modern Honeywell valves, if the powerhead fails it can be removed from the valve body without draining down. However,be warned!With very old Honeywell motorised valves the powerhead could not be removed without draining the water first. Honeywell V4044C1288 22mm 3-port diverter valve. This valve is not a mid-position valve. It opens either Port A or Port B (usually heating and hot water). Apart from the few moments when it is switching between ports, Port A and Port B are not open together. Note that it is a 3-wire valve, not a 5-wire valve

NatWest, RBS and Ulster Bank to close at least 172 branches in 2023/24 – here's the full list, plus alternatives V4043H1106 is a 2 port, 28mm compression, 6-wire, normally-closed zone valve with an auxiliary end switch Honeywell V4043H1056 22mm 2-port zone valves have five wires: green/yellow is Earth, blue is Neutral, brown is Live (or Line) to the motor, grey and orange are connected to the end switch and form part of a separate circuit. Slide the blunt end of the motor sideways until the flange comes out from the tab holding it down. This can be a bit of a fiddle. The motor then comes free of the valve, held only by the two wires which connect it electrically. These two wires may be blue (in a Honeywell original Synchron motor) or orange (most replacement Synchron motors).

Resideo products create the supported home

If the powerhead was removed from the valve to make it easier to change the motor, it must now be re-attached to the valve. The power head cover can then be refitted and secured with the single screw. Make sure it sits squarely on the powerhead, with no wires pushing out from the sides.

Inside a Honeywell V4073A 3-port motorised valve showing the rubber ball which closes one or other port, never both. The Honeywell valves have a D-shaped top to the spindle but you can also use a spanner on this. If you do this, you must use very little force as it is very easy to shear a spindle or damage the valve internally. Martin Lewis: What the Autumn Statement means for you – including wages, benefits, pensions, ISAs, national insurance and more The valve is fitted in the same way as the one adjacent to it for the hot water and he hasn't touched this at all.

Navigation

The Y Plan and S Plan names are more commonly used when other Honeywell controls are also used (programmer, room thermostat, cylinder thermostat and wiring centre).



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop